BNA-K301
Bypass Level Indicator Bypass tube Ø 63x3 mm Material PVC Max. temperature 60°C Thread connection and inspection junction (on top)
Max. Pressure 2.5 bar
Application Tanks in which due to their construction internal measurement is impossible, e.g. ship building, sewage works
BNA-K401
Bypass Level Indicator Bypass tube Ø 63x3 mm Material PVDF Max. temperature 140°C Thread connection and inspection junction (on top)
Max. Pressure 6.0 bar
Applications Tanks in which due to their construction internal measurement is impossible, e.g. shib building, sewage works
BNA-K701
Bypass Level Indicator Bypass tube Ø 63x3 mm Material PP Max. temperature 80 °C Thread connection and inspection junction (on top)
Max. Pressure 2.5 bar
Applications Tanks in which due to their construction internal measurement is impossible, e.g. shib building, sewage works
BNA-K302.0
Bypass Level Indicator Bypass tube Ø 63x3mm Material PVC Max. temperature 60 °C Flange connection and inspection junction (on top)
Max. Pressure 2.5 bar
Application Tanks in which due to their construction internal measurement is impossible, e.g. ship building, sewage works
BNA-K402.0
Bypass Level Indicator Bypass tube Ø 63x3 mm Material PVDF Max. temperature 140 °C Flange connection and inspection junction (on top)
Max. Pressure 6.0 bar
Application Tanks in which due to their construction internal measurement is impossible, e.g. ship building, sewage works
BNA-K702.0
Bypass Level Indicator Bypass tube Ø 63x3 mm Material PP Max. temperature 80 °C Flange connection and inspection junction (on top)
Max. Pressure 2.5 bar
Applications Tanks in which due to their construction internal measurement is impossible, e.g. shib building, sewage works
BNA-K302.1
Bypass Level Indicator Bypass tube Ø 63x3 mm Material PVC Max. temperature 60°C Top and bottom connection: DN 50
Max. Pressure 2.5 bar
Application Tanks in which due to their construction internal measurement is impossible, e.g. ship building, sewage works
BNA-K402.1
Bypass Level Indicator Bypass tube Ø 63x3 mm Material PVDF Max. temperature 140 °C Top and bottom connection: DN 50
Max. Pressure 6.0 bar
Application Tanks in which due to their construction internal measurement is impossible, e.g. ship building, sewage works
BNA-K303
Bypass Level Indicator Bypass tube Ø 63x3 mm Material PVC Max. temperature 60°C Side mounting: DN 15...DN 50
Max. Pressure 2.5 bar
Application Tanks in which due to their construction internal measurement is impossible, e.g. ship building, sewage works
BNA-K403
Bypass Level Indicator Bypass tube Ø 63x3 mm Material PVDF Max. temperature 140 °C Side mounting: DN 15...DN 50
Max. Pressure 6.0 bar
Application Tanks in which due to their construction internal measurement is impossible, e.g. ship building, sewage works
BNA-K703
Bypass Level Indicator Bypass tube Ø 63x3 mm Material PP Max. temperature 80 °C Side mounting: DN 15...DN 50
Max. Pressure 2.5 bar
Applications Tanks in which due to their construction internal measurement is impossible, e.g. shib building, sewage works